University of Washington Department of Microbiology
Standard Operating Procedures for Chemicals or
Processes
|
|||
|
#1
Process (if applicable) |
Injections of Benzene Standards for Gas
Chromatograph Calibrations and Sample Analyses (Note: All use of benzene is strictly
regulated by occupational health regulation WAC 296-62-07523.) |
||
|
#2
Chemicals |
Benzene, at known and
unknown concentrations. |
||
|
#3
Personal Protective
Equipment (PPE) |
Chemical splash
goggles, butyl or natural rubber gloves, and a lab coat or apron is required. |
||
|
#4
Environmental / Ventilation Controls |
Benzene-containing
solutions should be dispensed and used only in a fume hood. Syringe purging done in fume hood. |
||
|
#5
Special Handling Procedures & Storage Requirements |
Mixing and dispensing
done in an operating fume hood with all sources of ignition turned off (hot
plates, burners, etc.). Benzene
stored in metal safety cans or glass bottles (1 liter maximum) as much as
possible. Transported in
spill-proof carriers. Benzene is
stored in a flammable cabinet, separate from acids, bases, and
oxidizers. The flammable cabinet
is located * |
||
|
#6
Spill and Accident
Procedures |
Try to stop spill if
spill is on-going. If splash on
skin occurs, wash immediately with soap and water, and remove any
contaminated apparel while washing.
Call 9-911 in the event of a spill beyond labÕs capabilities. Remove all sources of ignition from
the spill area. Respiratory
protection is required to clean up spills outside of fume hoods (and
respirator users must be properly certified). Use absorbent pads or vermiculite to clean up small fume
hood spills or to dike larger spills.
Absorbent pads are stored at * After clean-up, room
air must be monitored by EH&S prior to re-occupancy. |
||
|
#7
Waste Disposal |
Place used absorbent
in metal can with leak-proof lid.
Over-pack with additional absorbent. Seal can and label with ÒHazardous Waste LabelÓ and
contact EH&S (685-2848) for collection. |
||
|
#8
Special Precautions
for Animal Use (if applicable) |
* |
||
|
Particularly hazardous substance involved? |
X YES: |
Blocks #9 to #11 are Mandatory |
|
|
NO: |
Blocks #9 to #11 are Optional. |
||
|
#9
Approval Required |
Users must receive specific physical and
health hazard information and safe laboratory work practices training from
their supervisor. Representative
breathing zone air sampling shall be taken to ensure that exposures do not
exceed regulated levels.
(Contact EH&S for additional information.) |
||
|
#10 Decontamination |
Immediately wash with soap and water. |
||
|
#11 Designated Area |
Room *
. Special signage may be
required depending on air sampling results. |
||
|
Name: Title: |
|||
|
Signature: Date:
|
|||
Environmental Health and
Safety, Box 354400